Electrical Thermography

Electrical Infrared Thermography

Thermal inspections for 3-phase power systems, panels, MCCs, switchgear, transformers, disconnects, breakers, bus bars, VFDs, and industrial electrical rooms.

Capabilities

3-phase electrical distribution imaging
Breaker and disconnect thermal scans
Motor control center inspections
Transformer and bus connection imaging
Phase-to-phase thermal comparison
Overloaded circuit and loose connection detection support
Visible-light and thermal image documentation
Repair-priority reporting
Post-repair verification scans

Equipment Coverage

Panels
MCCs
Switchgear
Transformers
Disconnects
Breakers
Bus bars
VFDs
Industrial electrical rooms

Important Scope Language

Thermal imaging can help identify abnormal heat patterns associated with loose connections, overloads, imbalance, failing components, poor ventilation, and developing electrical faults. Findings should be reviewed and corrected by qualified electrical personnel.

Inspection Process

01

Pre-job coordination with facility safety and maintenance teams

02

Inspection planning around energized access limits and operating load

03

Thermal and visible-light capture under practical operating conditions

04

Severity ranking and recommended maintenance next actions

Deliverables

  • Executive summary for management review
  • Thermal finding sheets with visible-light references
  • Repair-priority recommendations
  • Baseline records for future annual or recurring inspections

Risk Priority Matrix

Priority 1

Critical

Immediate safety, fire, shutdown, or equipment failure concern.

Priority 2

Serious

Repair should be scheduled promptly.

Priority 3

Monitor

Abnormal condition; recheck under operating load or during next inspection cycle.

Priority 4

Baseline

No actionable anomaly observed; retain as reference record.

Safety Notice

OHM'S LAW THERMOGRAPHY, LLC provides inspection and reporting only. We do not perform electrical repairs, installations, modifications, permitting, troubleshooting for hire, cover removal, or corrective work. Customer site personnel or qualified electrical contractors remain responsible for equipment access, energized cover removal, repairs, and verification of electrical work under the facility's safety program.

Related Services

Request an Inspection

Build a repeatable infrared inspection program around your highest-risk electrical assets.

Start with a facility scan, align around safe access and operating conditions, and turn findings into planned maintenance follow-up instead of surprise downtime and emergency reaction work.

Request an Inspection
Request Inspection